35kv 200 300 400A Neutral Point Grounding Resistor Cabinet Distribution Transformers

Product Details
Customization: Available
Type: Neutral Point Grounding Resistor Cabinet for Trans
Model No.: Ly-Bnr
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Self-branded
The supplier has 3 Self-brands, check the Audit Report for more information
Patents Awarded
The supplier had awarded 3 patents, you can check the Audit Report for more information
to see all verified strength labels (24)
  • 35kv 200 300 400A Neutral Point Grounding Resistor Cabinet Distribution Transformers
  • 35kv 200 300 400A Neutral Point Grounding Resistor Cabinet Distribution Transformers
  • 35kv 200 300 400A Neutral Point Grounding Resistor Cabinet Distribution Transformers
  • 35kv 200 300 400A Neutral Point Grounding Resistor Cabinet Distribution Transformers
  • 35kv 200 300 400A Neutral Point Grounding Resistor Cabinet Distribution Transformers
  • 35kv 200 300 400A Neutral Point Grounding Resistor Cabinet Distribution Transformers
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Company Profile
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
LY-BNR-35
Installation
Fixed
Structure
Cabinet
Language
Chinese, English, Russian, etc
Loading Port
It Depends
Rated Voltage
35kv
Frequency
50Hz
Transport Package
Wooden Case or Others
Specification
As required
Trademark
LIANYUAN
Origin
China
Production Capacity
50000 Sets/Year

Product Description

Product Description

        Used for 6-35kV systems, in cable powered systems, the grounding capacitor current is relatively high. When the current exceeds the specified value, there is a possibility of arc grounding overvoltage. The purpose of using a resistor grounding method for the neutral point is to inject resistive current into the fault point, with the resistive component current being 1.05 to 1.1 times the capacitive component current. It is possible to limit the fault current moderately, improve the sensitivity of relay protection, and limit the fault point to only local minor damage. The transient overvoltage can be limited to 2.6 times the normal relative neutral point voltage to prevent arc overvoltage from damaging the main equipment. At the same time, it has a significant effect on the ferromagnetic resonance overvoltage.
       The resistors produced by our company are made of stainless steel or stainless steel electric heating alloy materials, which have the characteristics of high conductivity, high temperature coefficient, corrosion resistance, high temperature resistance, strong oxidation resistance, high tensile strength, and stable resistance value. The product operates safely and reliably.

35kv 200 300 400A Neutral Point Grounding Resistor Cabinet Distribution Transformers35kv 200 300 400A Neutral Point Grounding Resistor Cabinet Distribution Transformers

 

Product Parameters

35kv 200 300 400A Neutral Point Grounding Resistor Cabinet Distribution Transformers

Detailed Photos

35kv 200 300 400A Neutral Point Grounding Resistor Cabinet Distribution Transformers35kv 200 300 400A Neutral Point Grounding Resistor Cabinet Distribution Transformers

 

Company Profile

35kv 200 300 400A Neutral Point Grounding Resistor Cabinet Distribution Transformers

 

Certifications

35kv 200 300 400A Neutral Point Grounding Resistor Cabinet Distribution Transformers

 

FAQ

35kv 200 300 400A Neutral Point Grounding Resistor Cabinet Distribution Transformers

Send your message to this supplier