35kv 2200 2700 3300kVA Turn Controlled Automatic Tracking Compensation Arc Suppression Coil Transformer

Product Details
Customization: Available
Type: Arc Suppression Coil
Model No.: Ly-Pth-35kv
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Self-branded
The supplier has 3 Self-brands, check the Audit Report for more information
Patents Awarded
The supplier had awarded 3 patents, you can check the Audit Report for more information
to see all verified strength labels (24)
  • 35kv 2200 2700 3300kVA Turn Controlled Automatic Tracking Compensation Arc Suppression Coil Transformer
  • 35kv 2200 2700 3300kVA Turn Controlled Automatic Tracking Compensation Arc Suppression Coil Transformer
  • 35kv 2200 2700 3300kVA Turn Controlled Automatic Tracking Compensation Arc Suppression Coil Transformer
  • 35kv 2200 2700 3300kVA Turn Controlled Automatic Tracking Compensation Arc Suppression Coil Transformer
  • 35kv 2200 2700 3300kVA Turn Controlled Automatic Tracking Compensation Arc Suppression Coil Transformer
  • 35kv 2200 2700 3300kVA Turn Controlled Automatic Tracking Compensation Arc Suppression Coil Transformer
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • FAQ
Overview

Basic Info.

Model NO.
LY-PTH-35KV
Structure
Cabinet
Customization
Acceptable
Language
Chinese, English, Russian, etc
Loading Port
It Depends
Rated Voltage
35kv
Frequency
50Hz
Transport Package
Wooden Case or Others
Specification
As required
Trademark
LIANYUAN
Origin
China
Production Capacity
10000 Sets/Year

Product Description

Product Description

       For power systems with different voltage levels, the grounding method for neutral points is different. According to China's national conditions, the small current grounding operation mode is mainly used in the 6-66KV distribution system in China. In order to effectively prevent system arc grounding, eliminate grounding faults, and improve power supply quality, according to the new regulations of the national overvoltage protection design standards, arc suppression coil devices should be installed when the grid capacitance current exceeds 10A.

      The LY-PTH series turn controlled arc suppression coil device produced by our company adopts a standard industrial grade computer system, bus structure, multi-layer circuit board design, full-color large screen LCD screen, and full Chinese character display. It has the characteristics of stable and reliable operation, intuitive display, and strong anti-interference ability. At the same time, the system has complete parameter settings and information query functions. This system overcomes the limitation of small adjustment range of previous arc suppression coil devices and is capable of comprehensive adjustment.
35kv 2200 2700 3300kVA Turn Controlled Automatic Tracking Compensation Arc Suppression Coil Transformer
35kv 2200 2700 3300kVA Turn Controlled Automatic Tracking Compensation Arc Suppression Coil Transformer

35kv 2200 2700 3300kVA Turn Controlled Automatic Tracking Compensation Arc Suppression Coil Transformer

Product Parameters

35kv 2200 2700 3300kVA Turn Controlled Automatic Tracking Compensation Arc Suppression Coil Transformer
Working Principle:
     The adjustable turn arc suppression coil is equipped with multiple taps on the arc suppression coil, and an on load voltage regulating switch is used to adjust the taps of the arc suppression coil to change the inductance value. During normal operation of the power grid, the microcomputer controller measures the amplitude and phase changes of the current flowing through the arc suppression coil in real time, calculates the capacitance current to ground under the current mode of the power grid, and adjusts the on load voltage tap according to the pre-set minimum residual current value or detuning degree. The controller adjusts the on load voltage tap to the required compensation gear, quickly compensates after a grounding fault occurs, and quickly exits the compensation when the fault is eliminated. It can quickly compensate for non instantaneous single-phase grounding faults, continue to operate, and quickly determine the faulty line and trip.
Technical Index
1. System voltage level: 6KV ,10KV, 35KV ,66KV
2.Current regulation method: equal difference or ratio
3.Accuracy of capacitance current measurement: ±2%
4.Grounding information record: No less than 500 times
5.Control mode: pre adjustment
6.Communication method: RS485
7.Working power supply:AC/DC 220V/110V±10%
8.Power loss: less than 100W
9.Human computer interface: Full Chinese LCD display screen
10.Residual flow range: < 5A
11.Number of selected routes: maximum 48 routes for a single arc suppression coil

Main Features
1.The ARM chip serves as the core computing control unit, ensuring stable and reliable operation
2.Adopting a large screen LCD display, parameter display, setting, and query are convenient and intuitive
3.Accurate adjustment, fast speed, and wide adjustment range
4.Equipped with RS485 communication interface, it can achieve communication with the upper computer and achieve long-distance signal transmission
5.Can achieve sound and light control alarm function for single-phase grounding faults


Complete set of technical parameters for arc suppression coil:
Ground variable arc suppression coil complete

Voltage Serial Number Product Model Capacity Rated Voltage(KV) Rated Current(A)
6KV 1 XHDCZ-315/6 315 6.3/√3 86
2 XHDCZ-400/6 400 6.3/√3 110
3 XHDCZ-630/6 630 6.3/√3 173
10KV 4 XHDCZ-315/10 315 10.5/√3 52
5 XHDCZ-500/10 500 10.5/√3 82
6 XHDCZ-630/10 630 10.5/√3 105
7 XHDCZ-900/10 900 10.5/√3 150
8 XHDCZ-1000/10 1000 10.5/√3 165
9 XHDCZ-1200/10 1200 10.5/√3 200
20KV 10 XHDCZ-630/20 630 21/√3 52
11 XHDCZ-900/20 900 21/√3 74
12 XHDCZ-1200/20 1200 21/√3 100
13 XHDCZ-1600/20 1600 21/√3 132
35KV 15 XHDCZ-500/35 500 37/√3 23
16 XHDCZ-630/35 630 37/√3 30
17 XHDCZ-1100/35 1100 37/√3 51
18 XHDCZ-2200/35 2200 37/√3 103
19 XHDCZ-2700/35 2700 37/√3 126
20 XHDCZ-3300/35 3300 37/√3 154

Note: The above table is the commonly used typical specification parameters.Our LY-XHDCZ series neutral point grounding resisitance device can meet customer needs in all directions.
35kv 2200 2700 3300kVA Turn Controlled Automatic Tracking Compensation Arc Suppression Coil Transformer
   35kv 2200 2700 3300kVA Turn Controlled Automatic Tracking Compensation Arc Suppression Coil Transformer35kv 2200 2700 3300kVA Turn Controlled Automatic Tracking Compensation Arc Suppression Coil Transformer
35kv 2200 2700 3300kVA Turn Controlled Automatic Tracking Compensation Arc Suppression Coil Transformer
35kv 2200 2700 3300kVA Turn Controlled Automatic Tracking Compensation Arc Suppression Coil Transformer
35kv 2200 2700 3300kVA Turn Controlled Automatic Tracking Compensation Arc Suppression Coil Transformer35kv 2200 2700 3300kVA Turn Controlled Automatic Tracking Compensation Arc Suppression Coil Transformer35kv 2200 2700 3300kVA Turn Controlled Automatic Tracking Compensation Arc Suppression Coil Transformer35kv 2200 2700 3300kVA Turn Controlled Automatic Tracking Compensation Arc Suppression Coil Transformer

35kv 2200 2700 3300kVA Turn Controlled Automatic Tracking Compensation Arc Suppression Coil Transformer

FAQ

 

35kv 2200 2700 3300kVA Turn Controlled Automatic Tracking Compensation Arc Suppression Coil Transformer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier