Introduce:
Main Features:
1. The cabinet structure adopts an assembled type,and the circuit breakeer adopts a handcart floor standing structure.
2. Equipped with a brand new composite insulation vacuum circuit breaker,and featuring good interchangeablity,and easy replacement.
3. The handcart frame is equipped with a screw nut propulsion mechanism,which can easily move the handcart amd prevent damage to the propulsion structure due to misoperation.
4.All operations can be performed with the cabinet door closed.
5. The interlocking between the switch, handcart, and switch cabinet door adopts a mandodary mechanicallocking method to meet the "five prevention" function .
6. The cable room has amplespace and can connect multiple cables.
7.Quick grounding switch is used for grounding and closing short-circuit circuits.
8.The protection level of the shell is IP3X, and when the handcart door is open,the protection level is IP2X.
9.The product complies with GB3906-2006,DL/T404-2007,and adopts the international IEC298 standard as reference.
External dimensions of switchgear:
Technical parameters of prefabricated substation:
Main Technical Parameters of Vacuum Switchgear
Serial Number | Name | Unit | Numerical Value |
1 | Rated Voltage | kv | 40.5 |
4 | Rated Frequency | Hz | 50 |
5 | Rated Current | A | 1250,1600,2000 |
6 | Rated Short-time Withstand Current | KA | 20,25,31.5 |
7 | Rated Peak Withstand Current | KA | 50,63,80 |
8 | Rated Power Frequency Withstand Voltage | KV | 95/min |
9 | Rated Lightning Impulse Withstand Voltage | KV | 185 |
10 | Rated short-circuit duration | S | 4 |
11 | Protection Level | IP3X |
Main Technical Parameters of Vacuum Citcuit Braeker
Serial Number | Name | Unit | Numerical Value |
1 | Rated Voltage | KV | 40.5 |
2 | Rated Frequency | Hz | 50 |
3 | Rated Power Frequency Withstand Voltage | KV | 95/min |
4 | Rated Lightning Impulse Withstand Voltage | KV | 185 |
5 | Rated Current | A | 1250,1600,2000 |
6 | Rated Short-time Withstand Current | KA | 25,25,31.5 |
7 | Rated Short-circuit Breaking Current | KA | 25,25,31.6 |
8 | Rated Peak Withstand Current | KA | 50,63,80 |
9 | Rated short-circuit duration | ms | 4 |
10 | Opening Time | ms | 30≤t≤60 |
11 | Closing Time | ms | 50≤t≤100 |
12 | Rated Short-circuit Breaking Current Times | second | 20 |
13 | Mechanical Frequency | second | 10000 |
Name | Unit | Numerical Value | |
Rated Operating Voltage | Opening Coil | V | DC220/110,AC220/110 |
Closing Coil | V | DC220/110,AC220/110 | |
Rated Operating Current | Opening Coil | A | 0.96(220V).1.0(110V) |
Closing Coil | A | 0.96(220V).1.0(110V) | |
Energy Storage Motor Power | / | W | 230 |
Rated Voltage of Energy Storage Motor | / | V | DC220/110,AC220/110 |
Energy Storage Time | / | S | ≤12 |